431 fault codes for commercial ice machines, refrigeration controllers, walk-ins, ovens, fryers, dishwashers, washers and dryers. Find your brand, then your code. Codes can differ between control-board generations — if you are not sure, call us with the model number.

Manitowoc29 codes · Ice machineScotsman27 codes · Ice machineHoshizaki6 codes · Ice machineIce-O-Matic7 codes · Ice machineDixell13 codes · Reach-in refrigerator / freezer / prep tableDanfoss6 codes · Reach-in refrigerator / freezer / prep tableDelfield14 codes · Reach-in refrigerator / freezer / prep tableContinental Refrigerator3 codes · Reach-in refrigerator / freezer / prep tableTrue7 codes · Reach-in refrigerator / freezer / prep tableHeatcraft / Bohn / Larkin12 codes · Walk-in cooler / freezerDexter21 codes · Commercial washerContinental Girbau21 codes · Commercial washerSpeed Queen / Huebsch / UniMac18 codes · Commercial dryer, Commercial washerBeverage-Air8 codes · Reach-in refrigerator / freezer / prep tableTraulsen3 codes · Reach-in refrigerator / freezer / prep tableTurbo Air3 codes · Reach-in refrigerator / freezer / prep tableFollett4 codes · Ice machineKE2 Therm11 codes · Walk-in cooler / freezerCarel12 codes · Reach-in refrigerator / freezer / prep tableKolpak7 codes · Walk-in cooler / freezerMaytag Commercial44 codes · Commercial washerADC – American Dryer Corp.22 codes · Commercial dryerElectrolux Professional / Wascomat30 codes · Commercial dryer, Commercial washerMilnor9 codes · Commercial washerHobart20 codes · Commercial dishwasherFrymaster24 codes · Commercial fryerPitco8 codes · Commercial fryerHenny Penny8 codes · Commercial fryerRational17 codes · Commercial oven / combiTurboChef11 codes · Commercial oven / combiBlodgett6 codes · Commercial oven / combi
BrandCodeMeaning
ManitowocE01Long Freeze
ManitowocE02Long Harvest
ManitowocE03Power Loss
ManitowocE04Hi Cnd Temp / Wtr Cnd Fault
ManitowocE05HPC Fault
ManitowocE07Starving TXV
ManitowocE08TXV Fault
ManitowocE09Flood Evap 1
ManitowocE10Flood Evap 2
ManitowocE11Refrig Fault
ManitowocE12Curtain Fault
ManitowocE15Low Liq Temp
ManitowocE16Rmt Cnd Temp
ManitowocE19ITP Fault
ManitowocE20WTR Fault
ManitowocE21T1 Fault
ManitowocE22T2 Fault
ManitowocE23T3 Fault
ManitowocE24T4 Fault
ManitowocE25Bin Prb Fault (low)
ManitowocE26Bin Prb Fault (medium)
ManitowocE27Bin Prb Fault (high)
ManitowocE28AuCS
ManitowocE29USB COMM
ManitowocE30USB DNLD
ManitowocE31Safe Mode
ManitowocE32RS485 COMM
ManitowocE33KEYBOARD
ManitowocE34DISPLAY
Scotsman1Long freeze time, shutting down (flashing = retrying)
Scotsman2Long harvest time, shutting down (flashing = retrying)
Scotsman3Water filling slowly
Scotsman4High discharge temperature
Scotsman5Failed sump temperature sensor
Scotsman7Failed discharge temperature sensor
Scotsman8Short freeze cycle, retrying (flashing = thin ice)
ScotsmanF / F flashingFreeze cycle / pending freeze (status, not fault)
ScotsmanHHarvest cycle (status)
ScotsmanbBin full (status)
ScotsmanCClean cycle (status)
ScotsmanLBoard locked
ScotsmandTest mode
ScotsmanOOff
ScotsmanEFailed self test
Scotsman1No ice sensed, shutting down (flashing = retrying)
Scotsman2Auger motor high load, shutting down (flashing = retrying)
Scotsman3No water in reservoir
Scotsman4Refrigeration pressure too high or low
ScotsmanESelf test failed
ScotsmanWater light onWater pump defective or water level not sensed/too low
ScotsmanWater light blinks 2xWater inlet valve faulty
ScotsmanRefrigeration light onLow discharge / long freeze / hot gas valve faulty / exceeds max freeze time
ScotsmanRefrigeration blinks 1xHarvest error (cubes sensed)
ScotsmanRefrigeration blinks 2xHarvest error (no cubes sensed)
ScotsmanRefrigeration blinks 3xHigh discharge temperature
ScotsmanRefrigeration + water lights (running)Temperature sensors out of range
Hoshizaki1 beepEvaporator overheated during harvest (high temp safety)
Hoshizaki2 beepsTwo consecutive long harvests (20-min harvest backup)
Hoshizaki3 beepsTwo consecutive long freeze cycles
Hoshizaki4 / 5 beeps (older mech. bin control)Bin control K-4 connector short (4) / open (5) — KM-280/500/630/900
Hoshizaki6 beepsLow voltage
Hoshizaki7 beepsHigh voltage
Ice-O-MaticError 1Max freeze (~1 hr) then short harvest
Ice-O-MaticError 2Max harvest — ice did not drop within 7 min
Ice-O-MaticError 3Hour-long freeze + 7-min harvest
Ice-O-MaticError 4Thermistor failure
Ice-O-MaticError 5Max fill — fill took 5+ min
Ice-O-MaticError 6Max purge (2 min purge, off 10 min, retry)
Ice-O-MaticError 7Float switch did not open within 15 s of pump start (3 tries)
DixellP1Thermostat (room) probe failure
DixellP2Evaporator probe failure
DixellP3Third / auxiliary probe failure
DixellP4Fourth probe failure
DixellHAMaximum (high) temperature alarm
DixellLAMinimum (low) temperature alarm
DixellHA2 / LA2Condenser high / low temperature
DixelldADoor switch / door open alarm
DixellEA / EALExternal alarm
DixellCA / BALSerious external alarm — outputs off
DixellPALPressure switch alarm
DixellEEData / memory (EEPROM) failure
DixellrtcReal-time clock alarm
DanfossA01High temperature alarm
DanfossA02Low temperature alarm
DanfossA99High voltage alarm
DanfossE27Defrost sensor (S5) error
DanfossE29Air sensor (Sair) error
DanfossE30Condenser sensor (Sc) error
DelfieldE-1Box temperature sensor open/shorted or control faulty
DelfieldE-2Coil temperature sensor open/shorted or control defective
DelfieldE-6Defective potentiometer in unit control
DelfieldE-13Loose display-to-controller cable, or faulty display/control
DelfieldEr 1 / Er 5Software or hardware failure
DelfieldEr 2Faulty display module cable
DelfieldEr 3Temperature sensor open or shorted
DelfieldEr 4Evaporator sensor open or shorted
DelfieldEr 6Below low alarm setpoint
DelfieldEr 7Above high alarm setpoint
DelfieldE01Defective air sensor
DelfieldE02Faulty coil sensor
DelfieldLo / HiTemperature below / above setpoint
DelfieldLEACooling continuously over 24 h
Continental RefrigeratorE0Regulation probe — loose wire/connection
Continental RefrigeratorE1Evaporator probe faulty
Continental RefrigeratorE2Ambient probe / faulty control
TrueE1Thermostat (cabinet) probe failure
TrueE2Evaporator probe malfunction
TrueE3Auxiliary / display probe
TruetHi / HAHigh temperature alarm
TruetLo / LALow temperature alarm
TruedoDoor open alert
TrueP1Cabinet probe failure on Dixell-equipped units (see Dixell)
Heatcraft / Bohn / LarkinA1High box temperature
Heatcraft / Bohn / LarkinA2Low box temperature
Heatcraft / Bohn / LarkinA3System start-up failure
Heatcraft / Bohn / LarkinA4Input fault
Heatcraft / Bohn / LarkinE1Room temperature sensor shorted/open/missing
Heatcraft / Bohn / LarkinE2Defrost temperature sensor shorted/open/missing
Heatcraft / Bohn / LarkinE3Suction temperature sensor shorted/open/missing
Heatcraft / Bohn / LarkinE4Suction pressure transducer shorted/open/missing
Heatcraft / Bohn / LarkinE5Outdoor temperature sensor shorted/open/missing
Heatcraft / Bohn / LarkinE6Low superheat
Heatcraft / Bohn / LarkinE7Compressor shut down (HP/LP/oil switch open)
Heatcraft / Bohn / LarkinE9Multi-in / multi-out wiring error
DexterF1Door failed to close/lock after 3 tries
DexterF2Tub didn't fill within 7 min
DexterF3Controller memory error
DexterF4Controller communication error
DexterF5Pressure switch error (OPL)
DexterF6Wrong washer size for drive type
DexterF7Wrong size drive installed
DexterF8Tub didn't empty within 7 min
DexterF9Tub didn't reach spin speed within 200 s
DexterF10Tub didn't stop within 150 s after spin
DexterF11Drive size setting changed
DexterF12Controller internal error
DexterF13Controller can't communicate with drive
DexterF14Over-current on drive or motor
DexterF15Over-voltage on drive or motor
DexterF16Drive overheating
DexterF17Overload of drive or motor
DexterF18Ground fault to drive
DexterF19Low voltage to drive
DexterF20Internal drive error
DexterF21Data error between controller and drive
Continental GirbauALn/VAR 0Microprocessor-to-inverter comms failure
Continental GirbauALn/VAR 1Inverter disconnected
Continental GirbauALn/VAR 2Inverter detects comm failure
Continental GirbauALn/VAR 3Inverter overcurrent
Continental GirbauALn/VAR 4Motor thermal cutout (klixon) open
Continental GirbauALn/VAR 5DC bus overvoltage
Continental GirbauALn/VAR 6Inverter overheating
Continental GirbauALn/VAR 7General inverter failure
Continental GirbauALn/VAR 8Unidentified inverter / unbalance control failure
Continental GirbauALn/VAR 9Model and inverter configuration mismatch
Continental GirbauALn/AFaulty water supply — fill level not reached
Continental GirbauALn/EBlocked drain
Continental GirbauALn/LWater present when tub should be empty
Continental GirbauALn/SLPersistent overfill
Continental GirbauALn/HOTCycle stopped with hot bath
Continental GirbauALn/CSteam heat fault
Continental GirbauALn/ProbFaulty temperature sensor
Continental GirbauALn/bALUnbalance detected
Continental GirbauALn doorDoor fails to lock
Continental GirbauErr/000Machine ID error
Continental GirbauEnErEmergency stop open
Speed Queen / Huebsch / UniMacdoorDoor open
Speed Queen / Huebsch / UniMacE:0dPressure switch error
Speed Queen / Huebsch / UniMacE:PrPressure switch sequence error
Speed Queen / Huebsch / UniMacE:FLFill error (30 min)
Speed Queen / Huebsch / UniMacE:drDrain error
Speed Queen / Huebsch / UniMacE:dFDrive failure
Speed Queen / Huebsch / UniMacE:dLDoor lock error
Speed Queen / Huebsch / UniMacE:dODoor opened during cycle
Speed Queen / Huebsch / UniMacE:HTHeater error
Speed Queen / Huebsch / UniMacE:SPSPI communication error
Speed Queen / Huebsch / UniMacE:UbUnbalanced load
Speed Queen / Huebsch / UniMacAlrmBreak-in alarm
Speed Queen / Huebsch / UniMacE:OP / OPOpen temperature sensor
Speed Queen / Huebsch / UniMacE:SH / SHShorted temperature sensor
Speed Queen / Huebsch / UniMacE:07 / E:08Inoperative control
Speed Queen / Huebsch / UniMacEI:07 / EI:08Error writing RTC / EEPROM
Speed Queen / Huebsch / UniMacErrCoin error
Speed Queen / Huebsch / UniMacEC:xxSmart-card / card reader errors
Beverage-AirdEFDefrosting (normal)
Beverage-AirHiCabinet / air temperature above high alarm limit
Beverage-AirLoAir temperature below low alarm limit
Beverage-AirConCondenser temperature too high or too low
Beverage-Airdor / dOrDoor open too long
Beverage-AiruHi / uLiLine voltage above / below limit
Beverage-AirLEACompressor running continuously too long
Beverage-AirE01–E04Sensor S1–S4 unplugged, shorted or failed
TraulsenCLN-FILCondensing temperature reached 140°F or higher
TraulsendEFDefrost in progress (normal); ends at 45°F coil or 25/30-min backup
TraulsenALAlarm submenu — alarm codes not published; call Traulsen 800-825-8220
Turbo AirAlarm lightTurbo Air manuals do not publish numeric codes — alarm light only; call Turbo Air support or check the unit's controller label
Turbo AirDoor Open lightDoor is open
Turbo AirDefrost lightDefrost active (normal)
FollettHI AMPSAuger gearmotor over current limit (soft error)
FollettLO WATERWater not detected at low sensor within 10 s (soft)
FollettHI PRESSURERefrigeration pressure above 425 psi (soft)
FollettDRAIN CLOGWater near top of drain pan — drain not flowing (hard)
KE2 ThermAtSAAir temperature sensor alarm
KE2 ThermCLSACoil temperature sensor alarm
KE2 ThermHtAHigh temperature alarm
KE2 ThermLtALow temperature alarm
KE2 ThermPFPower failure
KE2 ThermSSA / OSAShorted / open sensor alarm (KE2 Temp)
KE2 ThermHSHHigh superheat alarm
KE2 ThermHCAHigh condensing temperature (high-side control)
KE2 ThermHdAHigh discharge temperature (high-side control)
KE2 ThermCHA / LHAHumidity board comm lost / low humidity
KE2 ThermCLAMenu item to clear alarms (hold until red LED blinks)
CarelrEVirtual control probe fault
CarelE0Room probe S1 fault
CarelE1Defrost probe S2 fault
CarelE2 / E3 / E4Probe S3–S5 fault
CarelLOLow temperature alarm
CarelHIHigh temperature alarm
CarelAFrAntifreeze alarm (manual reset)
CarelIAImmediate alarm from external contact
CarelCHT / chtHigh condenser temperature alarm / pre-alarm
CareldorDoor open too long
CarelEtcReal-time clock fault
CarelEE / EFEEPROM error (parameters)
KolpakDOOR OPEN ALARMDoor open longer than door alarm delay
KolpakDOOR TEMP SENSOR ALARMTemp 1 input shorted or open
KolpakROOMTEMP2/3 SENSOR ALARMTemp 2/3 input shorted or open
KolpakHIGH / LOW MONITOR TEMP2/3 ALARMTemperature above/below offset longer than delay
KolpakHIGH / LOW DOOR TEMP ALARMDoor temp above/below offset (door heater issue)
KolpakEXTERNAL ALARM 1-3External alarm input active
Kolpak888.8 readingSensor failure
Maytag Commerciald1Water level circuit failure on control
Maytag Commerciald3Water temp sensor error
Maytag Commerciald4Lid switch circuit failure
Maytag Commerciald5Blocked Coin 1 / circuit error
Maytag Commerciald7Slow fill
Maytag Commerciald8Slow drain
Maytag Commerciald9Low voltage
Maytag Commerciald12Motor sense circuit failure
Maytag Commerciald13Blocked Coin 2 / circuit error
Maytag Commerciald16No communication from debit card reader
Maytag CommercialF01Main control fault
Maytag CommercialF03Pressure sensor fault
Maytag CommercialF07Shifter/actuator fault
Maytag CommercialF11Motor control fault
Maytag CommercialF20Long fill
Maytag CommercialF21Long drain
Maytag CommercialF22Lid lock fault
Maytag CommercialF24Temperature sensor fault
Maytag CommercialF25Basket speed sensor fault
Maytag CommercialF26Lid switch fault
Maytag CommercialF27Overflow
Maytag CommercialF29Lid unlock fault
Maytag CommercialF32No fill
Maytag CommercialF70 / F71CCU to UI communication fault
Maytag CommercialF73 / F74UI EEPROM fault
Maytag CommercialF77Off-balance load
Maytag CommercialF01CCU error
Maytag CommercialF03 / F04Accelerometer failure (MHN33)
Maytag CommercialF11Motor control unit failure
Maytag CommercialF20Slow fill
Maytag CommercialF21Slow drain
Maytag CommercialF22Door lock error
Maytag CommercialF24Temperature sensor
Maytag CommercialF25Tachometer error
Maytag CommercialF26Door switch error
Maytag CommercialF27Overflow
Maytag CommercialF28CCU–MCU communication error
Maytag CommercialF29Door unlock error
Maytag CommercialF30Dispenser error (MAH22)
Maytag CommercialF31Motor overheating
Maytag CommercialF33Pump sensed disconnected
Maytag CommercialF34Load detected during clean cycle
Maytag CommercialHelp 0F / 33Oversuds not resolved
Maytag CommercialHelp 32More than 6 unbalance retries — spin aborted
ADC – American Dryer Corp.MAIN DOOR OPENEDMain door open
ADC – American Dryer Corp.LINT ACCESS OPENLint drawer open
ADC – American Dryer Corp.EXHAUST HIGH TEMP FAULTTumbler temperature above 220°F
ADC – American Dryer Corp.EXHAUST HIGH LIMIT FAULTExhaust temperature disk opened
ADC – American Dryer Corp.SAIL SWITCH CLOSED / OPEN FAULTAirflow (sail) switch in wrong state
ADC – American Dryer Corp.BURNER HIGH LIMIT FAULTBurner temperature disk opened
ADC – American Dryer Corp.BURNER IGNITION CONTROL FAULTNo gas valve signal from DSI module during ignition trial
ADC – American Dryer Corp.IGNITION FAULTNo flame after ignition trial
ADC – American Dryer Corp.FLAME FAULTFlame lost after ignition (5 retries)
ADC – American Dryer Corp.ROTATION FAULTTumbler not rotating
ADC – American Dryer Corp.OPEN EXHAUST TEMPERATURE PROBEExhaust probe open/shorted
ADC – American Dryer Corp.OPEN S.A.F.E. SYSTEM PROBE FAULTFire-suppression probe open/shorted
ADC – American Dryer Corp.LOW VOLTAGE FAULTSupply voltage too low
ADC – American Dryer Corp.BURNER PURGE FAULTGas valve signal present during prepurge
ADC – American Dryer Corp.MODEL ERRORWrong model selected in control
ADC – American Dryer Corp.EE PROM FAULT ###Memory error at location ###
ADC – American Dryer Corp.LINT dOOR / MAIN dOORLint drawer / main door opened during run
ADC – American Dryer Corp.dRUM Safety FAILTumbler hi-limit opened while heating
ADC – American Dryer Corp.SAIL SWITCH FAILSail switch closed before start
ADC – American Dryer Corp.NO AIRFLOWSail switch opened mid-cycle
ADC – American Dryer Corp.bURNER SAFETY FAILBurner hi-limit opened
ADC – American Dryer Corp.bURNER CONTROL FAILGas valve signal not received in time
Electrolux Professional / Wascomat10:1CPU tacho internal error
Electrolux Professional / Wascomat10:11Real-time clock out of order
Electrolux Professional / Wascomat10:15 / 10:16Machine stop / emergency stop input active
Electrolux Professional / Wascomat11:1No water — fill level not reached in ~10 min
Electrolux Professional / Wascomat11:2Door open during program
Electrolux Professional / Wascomat11:3Door lock fail
Electrolux Professional / Wascomat11:4 / 11:5Water temp sensor low (open) / high (short)
Electrolux Professional / Wascomat11:6Water in machine at program end
Electrolux Professional / Wascomat11:8No heating
Electrolux Professional / Wascomat11:9Drum overfilled
Electrolux Professional / Wascomat11:10Max drain time exceeded
Electrolux Professional / Wascomat11:12No level sensor
Electrolux Professional / Wascomat11:16Heating timeout
Electrolux Professional / Wascomat13:7Drum not rotating (barrier)
Electrolux Professional / Wascomat13:15Compressed air missing (barrier)
Electrolux Professional / Wascomat20:1Drum motor overheat
Electrolux Professional / Wascomat20:2 / 20:3No / lost motor communication
Electrolux Professional / Wascomat21:1 / 21:2MCU heatsink / motor too hot
Electrolux Professional / Wascomat21:5Motor short circuit
Electrolux Professional / Wascomat21:7 / 21:8Low / high DC voltage
Electrolux Professional / Wascomat21:13Unbalance switch active at start
Electrolux Professional / Wascomat21:15Motor not following (no tacho feedback)
Electrolux Professional / Wascomat22:1 / 22:2 / 22:3 / 22:4Drive overvoltage / undervoltage / phase failure / overcurrent
Electrolux Professional / Wascomat22:6 / 22:8Drive internal / power module overheat
Electrolux Professional / Wascomat12:1 / 12:2Overheat thermostat inlet / outlet air
Electrolux Professional / Wascomat12:3–12:6Inlet/outlet air sensor open or shorted
Electrolux Professional / Wascomat12:11 / 12:12 / 12:13Drying error — stop value not reached within ~90 min
Electrolux Professional / Wascomat12:14Gas error — no flame
Electrolux Professional / Wascomat12:15No vacuum (airflow)
Electrolux Professional / Wascomat12:17Airflow obstructed — clean filter
MilnorE0Door-closed signal lost after latch locked
MilnorE1Door latch lock not confirmed in 5 s
MilnorE2Coin acceptor pulses out of spec
MilnorE3Level switch 'made' before wash
MilnorE4Water level not reached in 10 min
MilnorE5Water still present 40 s into drain
MilnorE6Inverter fault
MilnorE7 xInput stuck at power-up (attendant switch, coin, level, vibration, select/start)
MilnorE9 HDoor latch handle not fully closed at start
HobartE0, E2, E3, E4Not filling or not filling high enough — unit won't run
HobartE5Not draining properly
HobartE6Needs service
HobartCL / PrFilling too high or leaking from door
HobartP1, P2, P3 (wrench)Needs service
HobartWASH ARM ALERTWash arm obstructed or clogged
HobartLOW RINSE TEMPLow rinse temperature on consecutive cycles
HobartWASH / BOOSTER / RINSE TEMP SENSORProbe out of range
HobartFILL ERRORTimed out before filling
HobartDRAIN ERRORDrain problem — unit powers down
HobartSUMP / BOOSTER LEVEL SENSORPressure switch out of range
HobartClear Conveyor JamRack jammed
HobartProbe Err – TANKLower float issue in tank
HobartProbe Error – FnlRnsFinal rinse probe issue
Hobart01, 02Boiler temperature sensor
Hobart05, 06Tank temperature sensor high/low
Hobart07–10Pressure sensor high/low
Hobart13Tank filling pressure sensor monitor
Hobart14Wash tank draining during pump-out
Hobart17, 18, 31Filling monitoring — check water supply
FrymasterE01 / E02REMOVE DISCARD right/left — setpoint differs from vat temp
FrymasterE03Temperature probe failure
FrymasterE04HI 2 BAD — high-limit reading out of range
FrymasterE05HOT HI 1 — high limit above 410°F
FrymasterE06HEATING FAILURE — controller, interface board, contactor, gas valve, open high limit
FrymasterE07 / E08MIB software error
FrymasterE09Pump not filling — dirty filter pad or pump
FrymasterE10 / E11Drain valve not open / not closed
FrymasterE12 / E13Return valve not open / not closed
FrymasterE14AIF board error
FrymasterE15MIB board error
FrymasterE16 / E17AIF / ATO probe out of range
FrymasterE19M3000 CAN TX full — lost communication
FrymasterE20Invalid code location (SD card removed)
FrymasterE21Change filter pad / procedure error
FrymasterE22Oil in pan error
FrymasterE23Clogged drain (gas)
FrymasterE24AIF OIB failed (gas)
FrymasterE25 / E26Recovery fault (recovery time exceeded)
FrymasterE27 / E28Low / high temp alarm
FrymasterPROBFailed temperature probe or controller
FrymasterHOTFrypot above 410°F — turn off
FrymasterHELPHeating problem
FrymasterCALL TECHMemory chip failure
PitcoHeat feedback flashes 7xDrain valve detected open — heat cut
PitcoHeat feedback flashes 3xThermal probe open or shorted
PitcoDrn / DRAINING TURN OFFDrain detected open
PitcoProb / PROBE OPENProbe fault
PitcoHi / HIGH TMPOil too hot or probe misreading
PitcoIgnition Failure / HEAT FAILUREIgnition lockout / high limit tripped / weak pilot
PitcoSYSTEM FAILUREPossibly shorted probe
PitcoLoCProgram mode locked
Henny PennyE-4Control board overheating (CPU TOO HOT)
Henny PennyE-5Oil/shortening overheating
Henny PennyE-6Temperature probe error
Henny PennyE-10High limit tripped
Henny PennyE-15Drain open while fryer on
Henny PennyE-20Gas ignition system error (A–D sub-codes)
Henny PennyE-41Lost programming
Henny PennyE-46EEPROM write error
RationalService 10SC pump high water level
RationalService 11 / 12CDS sensor too many pulses / no signal
RationalService 13 / 14Steam generator not refilling / level electrode not detecting water
RationalService 17–19SD card not initialized / defective / missing
RationalService 20.xDefective thermocouple (cabinet, quench, humidity, steam gen)
RationalService 23 / 24SSR steam / hot air short circuit
RationalService 25Improper water flow during CleanJet
RationalService 26 / 27Drain valve closed / won't close
RationalService 28Steam generator above 180°C
RationalService 29PCB above 85°C
RationalService 30Emergency humidity control
RationalService 31.xFaulty core probe
RationalService 32 / 33Ignition box fault (gas)
RationalService 34.xBus signal problem (fan motor / ignition)
RationalService 36 / 37Differential pressure sensor
RationalService 40–44Care pump / solenoids / CleanJet+Care faults
RationalService 100 / 120SC pump or Care pump / level electrode
TurboChefF1Blower running status bad
TurboChefF2Cook temperature low
TurboChefF3Magnetron current low
TurboChefF4Door monitor defective (i3/i5) / E-stop pressed (conveyor)
TurboChefF5Magnetron / cook cavity over temperature
TurboChefF6Electrical compartment temperature high
TurboChefF7RTD open (shows 999°)
TurboChefF8Heat low / high limit tripped (conveyor)
TurboChefF9Cook cavity temp high / belt run failure (conveyor)
TurboChefF10UI–I/O board communication failure
TurboChefF12Firmware reboot
BlodgettCavity Probe ErrorCavity probe below 32°F or above 575°F
BlodgettCavity High Temp ErrorCavity above 565°F or 150°F over setpoint
BlodgettCooling Fan / Quench Probe ErrorProbe out of range
BlodgettFan ErrorFan drive @speed signal missing 15 s
BlodgettCom ErrorLost COM signal from relay board
BlodgettHigh Temp ErrorManual-reset high limit tripped (>671°F)