Commercial Equipment Troubleshooting Guides
Symptom → the causes a technician checks first. Safe first steps for staff are on each equipment page; anything electrical, gas or refrigerant should be handled by a qualified technician.
Ice machine
| Symptom | Common causes |
|---|---|
| Not making ice / low production | Dirty condenser coil or failed condenser fan; hot ambient (>90°F) or poor clearance; low/no water supply, clogged filter; scale on evaporator; failed water pump; refrigerant leak / weak compressor; bin control stuck 'full'. |
| Long freeze cycle (E01 / 3 beeps / Error 1) | Condenser airflow, water inlet valve leaking into sump, hot gas valve leaking by, TXV, low charge, float switch, dirty evaporator. |
| Ice won't release / long harvest | Scale on evaporator (clean & descale), hot gas valve not opening, harvest assist, curtain switch, machine not level, thermistor. |
| Small, cloudy, hollow or incomplete cubes | Low water flow, clogged distribution tube, dirty machine, wrong ice thickness probe setting, machine not level, low water pressure. |
| Water leaking | Clogged/obstructed drain, cracked water trough, bad float, distribution tube off, bin drain blocked. |
| Machine runs but bin overflows | Bin control/thermostat or bin level probe failed, curtain switch stuck. |
| Slime / mold / odor | Missed cleaning schedule; run clean + sanitize, replace filter, check air quality (yeast near bakeries/bars). |
Reach-in refrigerator / freezer
| Symptom | Common causes |
|---|---|
| Running but not cooling | Dirty condenser coil (most common), condenser fan failed, iced evaporator (defrost failure), evaporator fan failed, low charge/leak, failed start relay/compressor. |
| Too warm / high temp alarm (HA, A01, Er 7, tHi) | Door left open or not closing, torn gasket, overloaded with warm product, blocked air vents, dirty condenser, defrost problem. |
| Freezing product (cooler) | Thermostat/setpoint too low, failed probe, insufficient clearance, controller fault. |
| Iced-up evaporator | Defrost heater, defrost termination sensor (P2/E2), defrost timer/controller, door gasket letting in humid air. |
| Water on floor / inside | Clogged drain tube, frozen drain line (freezer, failed drain heater), condensate pan heater/float. |
| Runs constantly / short cycling | Dirty condenser, gasket leaks, low charge, bad probe, oversized load, ambient too hot. |
| Compressor won't start / clicking | Start relay/capacitor, overload, low voltage, failed compressor. |
| Probe error (P1/P2/E1/E2/E29) | Ohm the NTC probe vs. chart, inspect connector/wiring for water intrusion, replace probe, then controller. |
Prep table
| Symptom | Common causes |
|---|---|
| Top rail (pans) warm, cabinet OK | Lid left open, pans overfilled above line, dirty condenser, top-rail fan/air duct blocked, ambient heat from cook line. |
| Cabinet warm | Same as reach-in: condenser, gasket, evaporator fan, defrost. |
| Ice on cold wall / rail | Defrost failure, door gasket, humid kitchen air. |
| Water leaking under table | Clogged drain, evaporator pan, cracked drain tube. |
| Lid / hinge / cutting board issues | Worn hinge, warped lid gasket, damaged board brackets. |
Walk-in cooler / freezer
| Symptom | Common causes |
|---|---|
| Box temperature too high (A1) | Door not closing / heater strip, damaged gasket or sweep, evaporator iced, condenser dirty, low charge, failed compressor, failed EC fan motor. |
| Evaporator coil frozen solid | Defrost heater or termination failure, fan delay, defrost timer/controller settings, door ajar, low airflow. |
| Ice on floor / ceiling / door frame | Door heater wire failed, gasket gaps, panel seal, pressure relief vent. |
| System won't start (A3, E7) | High/low pressure switch open, oil pressure, low voltage, contactor, compressor. |
| Short cycling / pump-down issues | Liquid line solenoid leaking, low charge, LP switch setting, TXV. |
| Water leaking from evaporator | Drain line frozen (drain heater), clogged drain pan, pan not pitched. |
Cooler (bar / bottle / merchandiser)
| Symptom | Common causes |
|---|---|
| Not cold enough | Dirty condenser (lint/grease behind bar), blocked airflow, evaporator fan, overloading with warm product, door gasket. |
| Condensation on glass doors | Door heater/anti-sweat circuit, high humidity, gasket. |
| Lights out / ballast | LED driver or ballast, door switch. |
| Noisy | Fan blade hitting ice, loose panels, failing fan motor, unit not level. |
Commercial washer
| Symptom | Common causes |
|---|---|
| Won't start / door won't lock | Door lock or switch, door not closed, coin/payment system fault, control board, emergency stop open. |
| Won't fill / slow fill | Water supply valves, inlet screens, inlet valve, pressure switch/air dome tube, low water pressure. |
| Won't drain | Drain valve stuck/clogged, lint/debris, pump (if equipped), pressure switch tube, standpipe height. |
| Won't spin / spins slowly | Drive/inverter fault, motor, belt, out-of-balance load, bearings, braking resistor. |
| Excess vibration / walking | Unbalanced load, leveling, worn shocks/springs, mounting bolts (hard-mount extractors), bearings. |
| Leaking | Door boot/gasket, hoses, drain valve, tub seal/bearing (rust trail), dispenser. |
| Drive / inverter errors | Overcurrent, overvoltage, overheating — check motor turns freely, wiring, ground, cooling fan, line voltage. |
Commercial dryer
| Symptom | Common causes |
|---|---|
| No heat | Gas: igniter, flame sensor, gas valve coils, gas supply. Electric: element, contactor. Both: high-limit, thermistor, airflow switch, sail switch. |
| Long dry times | Lint screen and lint chamber, exhaust duct restricted or too long, blower wheel clogged, low gas pressure, overloading. |
| Overheating / high-limit trips | Restricted exhaust, failed blower, thermistor, cycling thermostat. |
| Drum won't turn | Belt, idler, drive motor, centrifugal switch, door switch. |
| Noisy / squeal | Drum rollers/bearings, idler pulley, belt, blower wheel loose. |
| Sensor errors (OP/SH) | Open or shorted thermistor — test and replace. |
Commercial dishwasher
| Symptom | Common causes |
|---|---|
| Dishes not clean / food residue | Clogged wash arms or nozzles, dirty strainers/scrap screens, low wash temperature, detergent pump not dosing, wrong water level, worn wash pump impeller. |
| Low rinse temperature / won't sanitize (LOW RINSE TEMP) | Booster heater element or thermostat, high limit tripped, low incoming water temperature, scale on element, chemical sanitizer pump empty (low-temp machines). |
| Won't fill / fill error | Water supply valve closed, clogged inlet strainer, fill solenoid, float or level probe dirty, low water pressure. |
| Won't drain / drain error | Food debris in drain, drain pump or drain valve failed, clogged drain hose, pressure switch tube blocked. |
| Leaking from door | Door gasket worn, overfilling (level probes dirty), machine not level, wash arm end caps missing. |
| Spots / white film on dishes | Hard water scale — delime the machine, check water softener, rinse-aid pump. |
| Conveyor jam (rack conveyors) | Rack caught, pawl bar or drive motor, broken curtains, overload. |
Commercial oven / combi oven
| Symptom | Common causes |
|---|---|
| Not heating | Gas: igniter, flame sensor, gas valve, ignition module, gas pressure. Electric: element, contactor, high limit tripped. Both: temperature probe, control board. |
| Uneven cooking / hot spots | Convection fan motor slow or failed, fan blade loose, door gasket leaking, wrong rack loading, failed element bank. |
| Temperature off from setpoint | Probe out of calibration, thermostat calibration, door seal, control board. |
| Convection fan won't run | Door switch, fan motor, motor capacitor, inverter (variable-speed models), relay. |
| Combi: no steam / low humidity | Scale in steam generator, water supply, solenoid, level electrode, water too pure (RO) or too hard. |
| Combi: CleanJet / cleaning faults | Low water pressure, clogged nozzle, care pump, drain valve. |
| Rapid-cook: F2 low cook temp | Clogged air nozzles/catalyst, door seal, heater, blower, low voltage. |
| Door won't close / glass condensation | Hinge, latch, door gasket, door adjustment. |
Commercial fryer
| Symptom | Common causes |
|---|---|
| Won't heat | Gas: pilot out, thermocouple, gas valve, igniter, ignition module. Electric: element, contactor. Both: high limit tripped, drain valve open (interlock), probe. |
| Oil overheating / high limit trips (E-5, HOT, Hi) | Probe out of calibration, thermostat stuck, gas valve stuck open, contactor welded. |
| Slow recovery (E25/E26) | Weak burner or element, low gas pressure, dirty burner/flue, failing probe. |
| Pilot won't stay lit | Thermocouple or thermopile, dirty pilot orifice, draft, gas valve. |
| Filtration problems (E09, pump won't fill) | Dirty filter pad, pump motor tripped, filter pan not seated, clogged lines, return/drain valve actuators. |
| Oil leaking | Drain valve seal, cracked frypot, high-limit or probe fittings, filter lines. |
| Pressure fryer won't build pressure | Lid gasket, deadweight valve, solenoid, lid not latched. |