Walk-In Cooler & Walk-In Freezer Repair in Charlotte, NC
Your walk-in holds most of the money in the building. We repair the whole system — the box, the door, the evaporator inside and the condensing unit on the roof or pad — for walk-in coolers and freezers of every brand.

What we fix
- Box temperature too high (A1, HtA, HI alarms)
- Evaporator coil frozen solid / defrost failure
- Door won't seal, broken closers, failed door heater wire
- Condensing unit not running, tripping pressure switches
- KE2, Beacon II, Dixell and Danfoss controller programming
- Refrigerant leak search and repair, compressor replacement
- Quarterly preventive maintenance
How a service call works
- Call or send the form — tell us the brand, model and any error code.
- We confirm a time window, same day whenever possible.
- The technician diagnoses the unit and gives you a written estimate.
- You approve; we repair on the spot or return with the part.
- You get a service report with temperatures and parts used.
Request service
Common problems we fix
| Symptom | Usual causes we check |
|---|---|
| Box temperature too high (A1) | Door not closing / heater strip, damaged gasket or sweep, evaporator iced, condenser dirty, low charge, failed compressor, failed EC fan motor. |
| Evaporator coil frozen solid | Defrost heater or termination failure, fan delay, defrost timer/controller settings, door ajar, low airflow. |
| Ice on floor / ceiling / door frame | Door heater wire failed, gasket gaps, panel seal, pressure relief vent. |
| System won't start (A3, E7) | High/low pressure switch open, oil pressure, low voltage, contactor, compressor. |
| Short cycling / pump-down issues | Liquid line solenoid leaking, low charge, LP switch setting, TXV. |
| Water leaking from evaporator | Drain line frozen (drain heater), clogged drain pan, pan not pitched. |
Brands we service
Error codes for this equipment
Look up what the display is telling you:
Heatcraft / Bohn / Larkin
A1 A2 A3 A4 E1 E2 E3 E4 E5 E6 E7 E9
KE2 Therm
AtSA CLSA HtA LtA PF SSA / OSA HSH HCA HdA CHA / LHA CLA
Kolpak
DOOR OPEN ALARM DOOR TEMP SENSOR ALARM ROOMTEMP2/3 SENSOR ALARM HIGH / LOW MONITOR TEMP2/3 ALARM HIGH / LOW DOOR TEMP ALARM EXTERNAL ALARM 1-3 888.8 reading
Serving the Charlotte area
Walk-In Cooler & Walk-In Freezer Repair in Charlotte, Concord, Gastonia, Huntersville, Matthews, Mint Hill, Cornelius, Davidson, Mooresville, Kannapolis, Harrisburg, Monroe, Indian Trail, Pineville, Belmont, Mount Holly, Fort Mill, SC, Rock Hill, SC, Tega Cay, SC, Lake Wylie, SC.