Rational Error Codes
What Rational fault codes and alarms mean, and what a technician checks for each one. Need it fixed? We repair Rational equipment across the Charlotte area.
SelfCookingCenter whitefficiency – Service codes
| Code | Meaning | What to check |
|---|---|---|
| Service 10 | SC pump high water level | Drain SC pump hose. |
| Service 11 / 12 | CDS sensor too many pulses / no signal | |
| Service 13 / 14 | Steam generator not refilling / level electrode not detecting water | Low conductivity — RO water. |
| Service 17–19 | SD card not initialized / defective / missing | |
| Service 20.x | Defective thermocouple (cabinet, quench, humidity, steam gen) | |
| Service 23 / 24 | SSR steam / hot air short circuit | |
| Service 25 | Improper water flow during CleanJet | |
| Service 26 / 27 | Drain valve closed / won't close | |
| Service 28 | Steam generator above 180°C | |
| Service 29 | PCB above 85°C | Air filter, cooling fan. |
| Service 30 | Emergency humidity control | |
| Service 31.x | Faulty core probe | |
| Service 32 / 33 | Ignition box fault (gas) | |
| Service 34.x | Bus signal problem (fan motor / ignition) | |
| Service 36 / 37 | Differential pressure sensor | |
| Service 40–44 | Care pump / solenoids / CleanJet+Care faults | |
| Service 100 / 120 | SC pump or Care pump / level electrode |