Indigo / Indigo NXT (E-codes)

CodeMeaningWhat to check
E01Long FreezeFreeze cycle runs longer than allowed. Check condenser airflow/cleanliness, water flow, scale, ice thickness probe, refrigeration.
E02Long HarvestHarvest cycle longer than allowed. Check hot gas valve, harvest assist, water curtain, scale on evaporator.
E03Power LossInput power interrupted or lost.
E04Hi Cnd Temp / Wtr Cnd FaultCondenser too hot (air- or water-cooled). Clean condenser, check fan, water regulating valve.
E05HPC FaultHigh-pressure control opened.
E07Starving TXVEvaporator starved of refrigerant (TXV or low charge).
E08TXV FaultFault in single- or dual-circuit evaporator TXV.
E09Flood Evap 1Evaporator flooding (single circuit, single evaporator).
E10Flood Evap 2Evaporator flooding (dual circuit, single evaporator).
E11Refrig FaultRefrigeration system fault (air/water-cooled).
E12Curtain FaultCurtain switch open for over 24 hours.
E15Low Liq TempLow ambient: liquid line below 60°F for over 1 minute during freeze.
E16Rmt Cnd TempRemote condenser: liquid line below 40°F or above 140°F for over 1 minute during freeze.
E19ITP FaultIce thickness probe fault.
E20WTR FaultWater system fault.
E21T1 FaultT1 temperature sensor problem.
E22T2 FaultT2 temperature sensor problem.
E23T3 FaultT3 temperature sensor problem.
E24T4 FaultT4 temperature sensor problem.
E25Bin Prb Fault (low)Bin level probe, low sensor.
E26Bin Prb Fault (medium)Bin level probe, medium sensor.
E27Bin Prb Fault (high)Bin level probe, high sensor.
E28AuCSAuCS board missing or not connected.
E29USB COMMDefective or missing USB drive.
E30USB DNLDDownload error from defective USB drive.
E31Safe ModeMachine running in safe mode.
E32RS485 COMMNo communication between control board and RS485 device.
E33KEYBOARDKeyboard faulty or unplugged from control board.
E34DISPLAYDisplay fault (verify against service manual).