Ice-O-Matic Error Codes
What Ice-O-Matic fault codes and alarms mean, and what a technician checks for each one. Need it fixed? We repair Ice-O-Matic equipment across the Charlotte area.
CIM / Elevation series (reset: hold Power + Clean 3 s)
| Code | Meaning | What to check |
|---|---|---|
| Error 1 | Max freeze (~1 hr) then short harvest | Condenser fan motor, compressor, inlet valve overfilling, dirty condenser/evaporator, float switch. |
| Error 2 | Max harvest — ice did not drop within 7 min | Hot gas valve or curtain switch not opening, relay or gas valve stuck. |
| Error 3 | Hour-long freeze + 7-min harvest | Compressor, water pump or condenser fan failure, board/relay, leaking harvest assist. Call IOM tech support. |
| Error 4 | Thermistor failure | Replace thermistor. |
| Error 5 | Max fill — fill took 5+ min | Clogged filter, inlet valve, water supply off, float switch. |
| Error 6 | Max purge (2 min purge, off 10 min, retry) | Water pump or purge valve, float switch. |
| Error 7 | Float switch did not open within 15 s of pump start (3 tries) | Float switch, leaking inlet valve, high water pressure, connections. |
Related service: Commercial Ice Machine Repair in Charlotte, NC