Beverage-Air Error Codes

What Beverage-Air fault codes and alarms mean, and what a technician checks for each one. Need it fixed? We repair Beverage-Air equipment across the Charlotte area.

Eliwell / Danfoss controllers (BZ, MMR and others)

CodeMeaningWhat to check
dEFDefrosting (normal)No action.
HiCabinet / air temperature above high alarm limitConfirm doors/drawers closed; clears automatically.
LoAir temperature below low alarm limit
ConCondenser temperature too high or too lowClean condenser, check condenser fan.
dor / dOrDoor open too longClose door; if persists, service.
uHi / uLiLine voltage above / below limitCheck supply voltage.
LEACompressor running continuously too longCheck doors closed; else service.
E01–E04Sensor S1–S4 unplugged, shorted or failedCall for service.