Dexter Error Codes
What Dexter fault codes and alarms mean, and what a technician checks for each one. Need it fixed? We repair Dexter equipment across the Charlotte area.
WCAD / T-series vended & OPL washers (F-codes)
| Code | Meaning | What to check |
|---|---|---|
| F1 | Door failed to close/lock after 3 tries | Check door/lock switch and wiring. |
| F2 | Tub didn't fill within 7 min | Water valves, inlet pressure, drain valve. |
| F3 | Controller memory error | Power off 1 min; replace controller if recurs. |
| F4 | Controller communication error | |
| F5 | Pressure switch error (OPL) | Replace pressure switch. |
| F6 | Wrong washer size for drive type | |
| F7 | Wrong size drive installed | |
| F8 | Tub didn't empty within 7 min | Drain valve, pressure switch tube. |
| F9 | Tub didn't reach spin speed within 200 s | Tub binding; else replace drive. |
| F10 | Tub didn't stop within 150 s after spin | Braking resistors / drive. |
| F11 | Drive size setting changed | |
| F12 | Controller internal error | |
| F13 | Controller can't communicate with drive | Data cable. |
| F14 | Over-current on drive or motor | |
| F15 | Over-voltage on drive or motor | Braking resistors, line voltage. |
| F16 | Drive overheating | Cooling fins, fan. |
| F17 | Overload of drive or motor | |
| F18 | Ground fault to drive | |
| F19 | Low voltage to drive | |
| F20 | Internal drive error | |
| F21 | Data error between controller and drive |
Related service: Commercial Washer & Dryer Repair in Charlotte, NC