Continental Girbau Error Codes
What Continental Girbau fault codes and alarms mean, and what a technician checks for each one. Need it fixed? We repair Continental Girbau equipment across the Charlotte area.
E-Series Logi / LogiPro / Vended
| Code | Meaning | What to check |
|---|---|---|
| ALn/VAR 0 | Microprocessor-to-inverter comms failure | Inverter power, fuses, ground, comm cable. |
| ALn/VAR 1 | Inverter disconnected | |
| ALn/VAR 2 | Inverter detects comm failure | |
| ALn/VAR 3 | Inverter overcurrent | Basket binding, drain debris, bearings, windings. |
| ALn/VAR 4 | Motor thermal cutout (klixon) open | |
| ALn/VAR 5 | DC bus overvoltage | Replace inverter. |
| ALn/VAR 6 | Inverter overheating | |
| ALn/VAR 7 | General inverter failure | |
| ALn/VAR 8 | Unidentified inverter / unbalance control failure | |
| ALn/VAR 9 | Model and inverter configuration mismatch | |
| ALn/A | Faulty water supply — fill level not reached | |
| ALn/E | Blocked drain | |
| ALn/L | Water present when tub should be empty | |
| ALn/SL | Persistent overfill | |
| ALn/HOT | Cycle stopped with hot bath | |
| ALn/C | Steam heat fault | |
| ALn/Prob | Faulty temperature sensor | |
| ALn/bAL | Unbalance detected | |
| ALn door | Door fails to lock | |
| Err/000 | Machine ID error | Jumpers X18/X19. |
| EnEr | Emergency stop open |
Related service: Commercial Washer & Dryer Repair in Charlotte, NC