ADC – American Dryer Corp. Error Codes
What ADC – American Dryer Corp. fault codes and alarms mean, and what a technician checks for each one. Need it fixed? We repair ADC – American Dryer Corp. equipment across the Charlotte area.
Phase 7 OPL microprocessor
| Code | Meaning | What to check |
|---|---|---|
| MAIN DOOR OPENED | Main door open | |
| LINT ACCESS OPEN | Lint drawer open | |
| EXHAUST HIGH TEMP FAULT | Tumbler temperature above 220°F | Check exhaust, lint, airflow. |
| EXHAUST HIGH LIMIT FAULT | Exhaust temperature disk opened | |
| SAIL SWITCH CLOSED / OPEN FAULT | Airflow (sail) switch in wrong state | Exhaust restriction, blower, switch. |
| BURNER HIGH LIMIT FAULT | Burner temperature disk opened | |
| BURNER IGNITION CONTROL FAULT | No gas valve signal from DSI module during ignition trial | |
| IGNITION FAULT | No flame after ignition trial | Gas supply, igniter, flame sensor, gas valve. |
| FLAME FAULT | Flame lost after ignition (5 retries) | |
| ROTATION FAULT | Tumbler not rotating | Belt, motor, rotation sensor. |
| OPEN EXHAUST TEMPERATURE PROBE | Exhaust probe open/shorted | |
| OPEN S.A.F.E. SYSTEM PROBE FAULT | Fire-suppression probe open/shorted | |
| LOW VOLTAGE FAULT | Supply voltage too low | |
| BURNER PURGE FAULT | Gas valve signal present during prepurge | |
| MODEL ERROR | Wrong model selected in control | |
| EE PROM FAULT ### | Memory error at location ### |
Phase 6 OPL
| Code | Meaning | What to check |
|---|---|---|
| LINT dOOR / MAIN dOOR | Lint drawer / main door opened during run | |
| dRUM Safety FAIL | Tumbler hi-limit opened while heating | |
| SAIL SWITCH FAIL | Sail switch closed before start | |
| NO AIRFLOW | Sail switch opened mid-cycle | Exhaust duct / lint. |
| bURNER SAFETY FAIL | Burner hi-limit opened | |
| bURNER CONTROL FAIL | Gas valve signal not received in time |
Related service: Commercial Washer & Dryer Repair in Charlotte, NC